You are here

Supply of Various Laboratory Equipment for the project “OR Petals: Operating Room Programmable Electronically Targeted Active Lighting”

Invitation Type: 
To Apply for Eligibility and to Bid
BAC/Group: 
BAC 3
Brief Description: 

Supply of Various Laboratory Equipment for the project “OR Petals: Operating Room Programmable Electronically Targeted Active Lighting”

One (1) Lot Light meter array and accessories
Inclusive of the following:
1 Unit Thermal Sensor Power Meter
Power Meter: Thermal sensor power meter
Operation: Bluetooth and USB operation
Wavelength rage: 190 nn to 10.6 um
Power Range: 100 uW to 2 W
1 Unit Light Source
Materials: Xenon and Mercury-Xenon Short-Arc
Wavelength rage: 240 to 2400 nm
1 Unit Silicon Photodiode
Materials: Silicon
Wavelength rage: 150-500 nm
Type: Mounted, Cathode Grounded

One (1) Lot Optical Component
Inclusive of the following:
1 Unit Flame Spectrometer
Wavelength rage: 200-1025 nm
Calibration: In house spectroradiometric UV-VIS calibration
Patch cords: QP600-1-SR-BX Premium-grade patch cords
Software: OceanView spectroscopy software with graphical UI
License: At least 1 license
1 Kit Reflective Neutral Density Filter
Rage: 200-1200 nm
Type: UVFS Reflective
Quantity: 10 pcs
Size: 25 mm diameter
Mount: SM-1 Mounted
Optical Densities: 0.1, 0.2, 0.3,0.4, 0.5, 0.6, 1.0, 2.0, 3.0, 4.0
1 Kit Optics Mounts Essentials Kit
Unit of measure: Metric
Size: 2” diameter
Drawer Dimensions (LxWxH): 10.89”x 5.50”x3.15”
Cabinet Dimensions (LxWxH): 17.13”x11.11”x11.08”
Kinematic Mount: 4pcs. Kinematic Mirror Mount for Ø2” Optics
5 pcs. Ø2” Clear-Edge Kinematic Mirror Mount, 2 Adjusters
4 pcs. Kinematic Mirror Mount for Ø2” Optics with Post-Centered Front Plate, 8-35 (M4) Taps.
4 pcs. Ø2” Kinematic Mirror Mount, 2 Differential Adjusters, 1 ¼” -80 Adjuster
2pcs. SM2 – Threaded Precision Kinematic Mirror Mount for Ø2” Optics, 3 Adjusters
Rotation and Translation Mounts: 2 pcs. Kinematic Rotation Mount for Ø2” Optics
3 pcs. Rotation Inner Carriage for Ø2” Optics, OneSM2RR Retaining Ring
3 pcs. Rotation Mounting Ring for LM2-A Ø2” Optic Carriage, 8-32 (M4) Tap
2 pcs. High-Precision Rotation Mount for Ø2” (50.8mm) Optics
2 pcs. Rotation Mount for Ø2” (Ø50.8 mm) Optics 8-32 (M4) Tap
2 pcs. Translating Lens Mount for Ø2” Optics, 1 Retaining Ring Included
Fixed Mounts: 5pcs. Lens Mount with Retaining Ring for Ø2” Optics, 8-32 (M4) Tap
5 pcs. Fixed Ø2” Mirror Mount, 8-32 (M4) Tap
3 pcs. 90° Flip Mount for Ø2” Filters and Optic, 8-32 (M4) Tap
2 pcs. 45° Mount for Ø2” Optics
2 pcs. UV/VIS Detector Card
Absorption Range: 250-549 nm
Emission Range: 450-750 nm
Quantity: 2 pcs.
Active Region: 2.10”x1.20”
Persistence of Emission: 6s to 4 min
1 pc. Compact Laser Module with USB Connector
Wavelength: 635 nm
Output power: 0.9 mW
Laser Safety Class: Class 2
Beam Shape: Round, Ø3 mm (Typical) at 5 cm
Housing Dimensions: Ø11.0 mm x 60.2 mm
1 pc. Compact Laser Module with USB Connector
Wavelength: 520 nm
Output power: 0.9 mW
Laser Safety Class: Class 2
Beam Shape: Round, Ø3 mm (Typical) at 5 cm
Housing Dimensions: Ø11.0 mm x 60.2 mm
1 pc. Compact Laser Module with USB Connector
Wavelength: 405 nm
Output Power: 0.9 mW
Laser Safety Class: Class 2
Beam Shape: Round, Ø3 mm (Typical) at 5 cm
Housing Dimensions: Ø11.0 mm x 60.2 mm

One (1) lot SLA 3D Printer: Formlabs SLA Printer Package (Form 2 + Form wash and Form)
Specifications:
Technology: SLA Low Force Stereolithography (LFS) technique
Layer thickness: 25-300 microns
Optic Engine: Light processing unit 250 mW laser power, 85 micron laser spot
Interference: Fully Integrated Touch-screen
Level sensing: Automated
Resin system: Automated
Software: with included Perform software
Connectivity: Wifi, Ethernet, LAN
Inclusions: Form 3 3D Printer, Resin Tank, Build Platform, Finishing Kit, Form Wash, and Form Cure
Accessories: Additional Build Platform and Resin Tank Form 3
Set-up and Installation: Includes 2 hr setup and installation hardware and software
Delivery: Within NCR included
Service: with 1-year Formlabs Pro-Service
Warranty: with Formlabs Extended Warranty Plan for 2 years
Resin: With Resin starter bundle (3x standard, 3x draft, 2x tough, 2x durable, and 2x rigid resin)

One (1) lot UV-VIS Spectrometer and Accessories
Specifications:
Unit: Double-beam UV-VIS Spectrometer
Operation: PC-controlled
Wavelength range: 190 to 1100nm
Spectral bandwidth: 1 nm
Wavelength display: 0.1 nm increments
Wavelength setting: 0.1 nm increments
Wavelength accuracy: 0.3 nm for entire range
Wavelength repeatability: 0.025 nm
Wavelength Slew rate: 29,000nm/min
Wavelength scanning speed: 3,000 to 2 nm/min
Photometric system: double beam optics
Photometric mode: single-wavelength and multiple-wavelength measurement
Photometric range: absorbance -4 to 4 ABS, 0 to 400% Transmittance
Noise level: Less than 0.00001 Abs
Light source: 20-W halogen lamp and deuterium lamp
Monochromator: LO-RAY-LIGH grade blazed holographic grating in Czemy-Turner-Mounting
Detector: Silicon photodiode
Software: Inclusive of LabSolutions UV Software
Training: Inclusive of end-user training
Accessories: 1 unit Film Holder and 2 pcs quartz cuvette (10mm path length)

Requesting Unit/Location: 
College of Medicine
Approved Budget: 
PHP3,451,300.00
Fund Source: 
Fund 184-2020105000 (416) 107-133 (DOST)
Contract Duration: 
Remarks: 